6040 membrane element
POSITION:HOME>6040 membrane element
|
|
6040 membrane element structure
Symbolic description:
Internal pressure type:
①liquid inlet/backwash drainage outlet/gas inlet
②permeate outlet/backwash water inlet
③permeate outlet/backwash water inlet
④concentrate outlet/chemical cleaning fluid outlet/gas outlet
External pressure type:
①liquid inlet/backwash drainage outlet/gas inlet/chemical cleaning fluid inlet
②often closed port/ backwash drainage outlet
③concentrate outlet/chemical cleaning fluid outlet/gas outlet
④permeate outlet/backwash water inlet
Notes:
Connections-Φ32
Design parameters
Title
|
Parameter
|
Influent limitations
|
Turbidity
|
≤5NTU
|
PH
|
1~12
|
Residual chlorine
|
≤0.01mg/l Cl2
|
Water temperature
|
5~35℃
|
Max. inlet water pressure
|
3.5bar
|
Effluent quality
|
Production capacity
|
0.8~1.5m3/h
|
Turbidity
|
≤5NTU
|
SDI15
|
≤3(clean water)
|
≤5(wastewater)
|
Transmembrane pressure
|
≤1.5bar(normal), ≤3bar(maximum)
|
|
|
|